GIS Testing System
Gas-insulated switchgears
GIS Testing Solution for Reliable High Voltage Performance
Gas-insulated switchgear (GIS) and gas-insulated transmission lines (GIL) require accurate and reliable testing systems throughout their lifecycle, including routine tests, type tests and on-site commissioning tests.
Yangzhou Sute provides customized high voltage testing solutions for GIS manufacturers, power equipment companies and research institutions, covering AC withstand testing, partial discharge measurement, impulse voltage testing and DC insulation testing.
GIS Testing Requirements
GIS testing involves different voltage levels, frequencies and power requirements depending on the testing stage.
-
check
AC WITHSTAND
-
check
PD
-
check
INSULATION
-
check
LIGHTNING IMPULSE
-
check
SWITCHING IMPULSE
-
check
ELECTRICAL PERFORMANCE
-
check
AC WITHSTAND
-
check
PD
-
check
DC INSULATION
High Voltage Testing Solutions for GIS
SF₆ Gas Testing Transformer
A compact SF₆-insulated solution for high voltage AC testing and associated partial discharge measurement of GIS and other high-voltage equipment.
Compact Design
High Insulation Strength
Low Partial Discharge
SF₆ FM Resonant Reactor
An efficient resonant testing solution for GIS, GIL and other large capacitive loads, designed for high-voltage AC withstand testing.
Variable Frequency
High Test Voltage
Reduced Power Requirement
High Voltage DC Generator
A stable high-voltage DC source for insulation and withstand testing of GIS and other high-voltage electrical equipment.
Stable DC Output
High Voltage Testing
Field Applications
Q & A
-
What tests are commonly performed on GIS?
GIS testing may include AC withstand testing, partial discharge measurement, impulse voltage testing and DC insulation testing depending on the test stage and applicable requirements.
-
What equipment is used for GIS AC withstand testing?
SF₆ gas testing transformers and variable frequency resonant test systems can be configured according to the voltage, capacity and characteristics of the GIS test object.
-
What is the difference between GIS routine testing and type testing?
Routine tests are generally performed on individual manufactured units to verify quality and insulation performance, while type tests evaluate the design under specified test conditions.
-
Can GIS testing equipment be used on site?
Yes. Compact and modular test systems can be configured for GIS commissioning, acceptance and maintenance testing at substations and other field locations.
-
Can SUTE customize a GIS testing system?
Yes. The testing system can be configured according to required test voltage, frequency, power capacity, test object and operating environment.
-
Do you provide any scripts?
Our templates do not include any additional scripts. Newsletter subscriptions, search fields, forums, image galleries (in HTML versions of Flash products) are inactive. Basic scripts can be easily added at www.TemplateTuning.com If you are not sure that the element you’re interested in is active please contact our Support Chat for clarification.